Your water heater this winter: trip the safety valve now and then, and let it drip

Ariston’s manual on scalding above 50°C, and the magnesium anode that wants replacing every two years.

How To 2 min read
Your water heater this winter: trip the safety valve now and then, and let it drip

Cold nights mean the water heater works harder than at any other time of year. Ariston’s installation and operating manual for its electric heaters has a handful of points worth knowing before winter sets in, and none of them needs a tool.

Trip the safety valve by hand from time to time

The safety valve sits on the cold-water pipe feeding the heater. It lets water out when pressure builds inside the tank as it heats, and stops water flowing back into the house supply. The manual says to trip it by hand now and then, to make sure it hasn’t seized and to clear out scale. Setting, fitting or replacing the valve is a job for a technician, Ariston says on its page about the part.

A drip while heating is normal

Water dripping from the safety valve while the heater is heating is normal, according to the manual. That is why the drain pipe has to stay connected and open, running continuously downhill. Don’t block it or tie it off, and don’t keep anything under the heater that water would ruin.

50°C is where burns start

Water hotter than 50°C can cause serious burns instantly if it reaches the tap directly, and children and older people are most at risk. The manual recommends fitting a thermostatic mixing valve, marked with a red collar, on the hot-water line.

Every two years: scale and the anode

As scheduled maintenance, for a qualified technician, the heating element should be descaled every two years and the magnesium anode replaced every two years, with a yearly check if the water is corrosive or high in chlorides. After servicing, the tank is filled and then drained completely to flush out any debris.

Before draining

The manual starts the draining steps with cutting the power for good, then opening a hot tap at the sink or bath. It also notes that the heater must be earthed.

Photo: the thermostat dial under a wall-mounted electric water heater. By Adoscam, CC BY-SA 4.0, via Wikimedia Commons.

Source: Ariston ANDRIS LUX electric water heater installation and operating manual, and Ariston Saudi Arabia’s page on water heater safety valves, both read on 26 November 2026.

Kuwait One, once a week.

The most useful stories we published this week, in your inbox.

No spam. Unsubscribe anytime.